Lead product line
Cathodic protection for the pipelines the region is building now.
Iraq is building new crude export lines, including the 700 km Basra–Haditha pipeline. Every metre of buried steel needs cathodic protection from the day it is laid, and that protection must be maintained for the life of the line. We supply the materials, equipment and specialist support from UK and European makers to projects in Iraq, the Middle East and Africa.
What we supply
| Group | Products |
|---|---|
| Galvanic (sacrificial) systems | Magnesium, zinc and aluminium anodes; pre-packaged anodes with backfill; bracelet anodes for subsea and river crossings |
| Impressed-current (ICCP) systems | Mixed-metal-oxide, high-silicon iron and graphite anodes; deep-well and shallow groundbed materials; carbonaceous backfill |
| Power and control | Transformer-rectifier units, air- or oil-cooled, including hazardous-area and remote-monitored versions |
| Monitoring and test | Test posts and stations, permanent reference electrodes, coupons, junction and bond boxes, remote monitoring units |
| Isolation and interference | Insulating joints and flange kits, surge protection, AC mitigation materials |
Applications
- Buried crude and gas export pipelines
- In-field flowlines and gathering networks
- Storage tank bottoms and internals
- Water injection and seawater supply lines
- Jetties, piling and marine structures
Standards
We supply to the standard your specification names, for example ISO 15589-1 (onshore pipelines), ISO 15589-2 (offshore pipelines) or AMPP SP0169 (formerly NACE). Each delivery comes with the maker's test certificates and data sheets, and the conformity certificate the destination country requires.
Survey and commissioning support
Close-interval potential surveys (CIPS), DCVG coating surveys, commissioning and periodic inspection can be scoped with our Basra partner for your project. Tell us what your specification requires.
Why it pays to plan CP early
Cathodic protection is not a one-off purchase. Anodes are consumed, rectifiers need service and surveys repeat on a schedule. We supply the first installation and the spares and inspections that follow, from the same approved makers.
What we need for a quotation
- Structure type, length and diameter
- Coating type and design life
- Soil or water resistivity data, if available
- Your specification or the standard to be met
- Delivery point and required date
Send us your CP specification
We will come back with approved makers and a priced proposal in USD or GBP.